Technical Data of MDF Terminal Blocks and Protection Modules

1. Operating Environment
Temperature : -25¡ã C
¨C 55¡ã C
Relative Humidity :
£ 95%
Atmosphere : 70
¨C 106 KPa

2. Vertical Protection Block & Horizontal Testing Block

a) Insulation Resistance:
The resistance between any two disconnected terminals, and between any terminal and fixed metal part is more than 10000Mohm;

b) There are no break-down and spark-discharge between any two disconnected terminals, and between any terminal and fixed metal part under 2000V, 45 ¨C 60Hz AC, lasting for 60 seconds;

c) Contact Resistance:
- between terminal and cable conductor at the V-slot:
£ 2mohm;
- between terminals of Vertical Protection Block and Protection Module:
£ 5mohm;

d) Suitable Wire:
Single plastic insulation wire with the conductor diameter: 0.32mm
¨C 0.70mm, with the outer diameter (including insulator) :
£ 1.40mm.

e) IDC Force:
- insertion force : < 3.0kg;

- pull-off force : ³ 2.5kg (vertical to V-slot);
- contact pressure between terminals of Vertical Protection Block and Protection Module: > 50g;
- reliable re-termination of conductor:
³ 200 times.

3. Protection Module:

a) DC break-down voltage: Udc = 230 +30/-40V;

b) Impulsive break-down voltage: Umax £ 800V ( at the voltage rising rate: 1000V/m s );

c) Protection Capability against Lightning:
keeping normal under impulsive voltage: 4kV, 10/700m s, 10 times with the interval 60 seconds, opposite electrodes for neighbouring two times;

d) Protection Capability against Induction of Power Lines:
keeping normal under Uac(max) = 650Vr.m.s, f = 50Hz, lasting for 500ms each time, total 5 times with interval of 60 seconds;

e) Protection Capability against Contact with Power Lines:
no fire, no burning under voltage Uac(max) = 220Vr.m.s, f = 50Hz, lasting for 15 minutes;

f) Fail-Safe Protection:
The line a or line b in circuit will earth within 15 seconds when discharge current reaches 2.5A in arrestors;

g) Normal Resistance : < 22 ohm; Difference between line a and line b : < 2 ohm;

h) Overcurrent Protection:
non-operation current: 100mA, 1 hour (at 60Vdc, 40¡ã C)


Current-Restriction Characteristics:

Current (A)

Operation Time (s)

Remark

SBAII type (PTC)

0.50

£ 20

Circuit isolated or current restricted to 150 mA

£ 8 s, recoverable

0.75 £ 5 £ 2 s, recoverable

1.00

£ 1.5

Circuit isolated or current restricted to 500 mA

£ 1 s, recoverable

2.00 £ 0.5 £ 0.2 s, recoverable
3.00 £ 0.2 £ 0.1 s, recoverable